XLHV Medium Voltage Series -
Mosebach Manufacturing Company
The XLHV range offers you a continuous load at higher voltages in an outdoor rated enclosure. These can be for AC or DC load banks up to 15kV.
-
Ohm Loads Powertek Inc.
Our STANDARD AC AND DC LOAD BANKS are easily configured for other voltage, current and power ratings. These MODIFIED STANDARD LOADS are built to the customer’s exact design specifications at Standard Load Bank pricing and shipping schedules. Our goal is to supply a product with input from the end-user.
-
Titan -
Simplex Inc
Very high capacity electrical loads, typically in excess of 10MW, for testing, maintenance and performance analysis of large AC power systems can be formed using the Simplex Titan Load Bank as a building block element. The Titan Load Bank is a self-contained, semi-portable unit providing resistive and inductive loads to 15KVA, .8 power factor, to 600VAC.
-
902804 -
Miller Electric Mfg Co.
The welding power load bank is designed to load test the output of transformer-type, engine- or motor-driven generator welding power sources. This unit can be used to test AC or DC welder outputs, and to demonstrate welding equipment to customers.
-
Load Cube -
Simplex Inc
The Simplex Load Cube is an ultra-large capacity, fully portable, resistive/reactive Load Bank System intended for field use in testing, maintenance and performance proving of large generating systems. The Load Cube is rated 2500KW, 1875KVAR at 400-600V commercial AC voltages. The Load Cube is typically used to test large diesel generators, turbines, paralleled generators and shipboard generators.
-
Simplex Inc
The Simplex Watt-Muncher is a small DC rated load bank used to test battery systems, AC to DC rectifiers and power supplies, battery chargers, UPS systems and DC generators. The Watt-Muncher provides a variable test load used to measure charge and discharge rates, response, stability and endurance. Corresponding calibrations and adjustments can be made while maintaining a constant, precise, resistive load on the power source.
-
Supreme Instrument Laboratories
Capacitive Bank Load Three phase suitable for operation on 415/440 volts three phase AC 50Hz housed in well ventilated sheet steel cabinet with bakelite front panel, complete with indicating lamps, voltmeter to indicate the input voltage and Ammeters to indicate, the load. ON/OFF switch, discharge switch etc. available in continuously variable type.
-
Swift -
Simplex Inc
Quick and easy testing of small generators is possible with the Simplex Swift-e Portable Load Bank. Fully self-contained, lightweight and hand transportable, the Swift-e can be used to test and maintain engine generators, inverters, batteries, battery chargers, rectifiers and small UPS systems. Swift-e's are available as AC or DC units with capacities up to 15,000 watts of load switchable in 250W increments.
-
40-659-102 -
Pickering Interfaces Ltd.
Model 40-659 is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC.The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
40-659A-102 -
Pickering Interfaces Ltd.
Model 40-659A is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC. The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
Bloomy Controls, Inc.
The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.
-
Junxy Energy
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.